Software development kitThe PicoScope 9000 software can be operated as a standalone oscilloscope program and as an ActiveX control. The ActiveX control conforms to the Windows COM model and can be embedded in your own software. Programming examples are provided in Visual Basic (VB.NET), LabVIEW and Delphi, but any programming language or standard that supports the COM standard can be used, including JavaScript and C. A comprehensive Programmer’s Guide is supplied that details every function of the ActiveX control. The SDK can control the oscilloscope over the USB port or the LAN port. |
Your opinion is very important to us. We appreciate your feedback and will use it to evaluate changes and make improvements in our products:
Here you can check the latest PicoScope 9200 Series specifications:
Channels (verctial) |
|
Channels | 2 (simultaneous acquisition) |
Bandwidth | |
Full | DC to 12 GHz |
Narrow | DC to 8 GHz |
Rise time (calculated) | 10% to 90%, tR = 0.35/BW |
Full bandwidth | 29.2 ps |
Narrow bandwidth | 43.7 ps |
Input connectors | SMA (F) |
ADC resolution | 16 bits |
Scale factors (sensitivity) | 2 mV/div to 500 mV/div. 1-2-5 sequence and 0.5% fine increments |
Nominal input impedance | (50 ±1) Ω |
Optical–electrical (O/E) converter (PicoScope 9221A and 9231A) |
|
Unfiltered bandwidth | DC to 8 GHz typical. DC to 7 GHz guaranteed at full electrical bandwidth) |
Effective wavelength range | 750 nm to 1650 nm |
Calibrated wavelengths | 850 nm (MM), 1310 nm (MM/SM), 1550 nm (SM) |
Transition time | 10% to 90% calculated from tR = 0.48 / BW: 60 ps max. |
RMS noise, maximum | 4 µW (1310 and 1550 nm), 6 µW (850 nm) |
Scale factors (sensitivity) | 1 µV/div to 400 µV/div (full scale is 8 divisions) |
DC accuracy, typical | (±25 µW ±10% of vertical scale |
Maximum input peak power | +7 dBm (1310 nm) |
Maximum input peak power | Single-mode (SM) or multi-mode (MM) |
Fiber input | +7 dBm (1310 nm) |
Fiber input connector | FC/PC |
Input return loss | |
SM | −24 dB, typical |
MM | −16 dB, typical; −14 dB, maximum |
Timebase (horizontal) |
|
Digitising rate | DC to 200 kHz maximum |
Timebases | 10 ps/div to 50 ms/div (main, intensified, two delayed, or dual delayed) |
Time interval resolution | 200 fs minimum |
Data record length | 32 to 4096 points maximum per channel in x2 sequence |
Delta time interval accuracy | |
For horizontal scale > 450 ps/div | ±0.2% of Delta Time Interval ±15 ps at a temperature within ±3 °C of horizontal calibration temperature. |
For horizontal scale = 450 ps/div | ±15 ps or ±5% of Delta Time Interval ±5 ps, whichever is smaller at a temperature within ±3 °C of horizontal calibration temperature. |
Acquisition modes | Sample (normal), average, envelope |
Dynamic performance (typical) |
|
RMS noise, maximum | |
Full bandwidth | 2 mV |
Narrow bandwidth | 1.5 mV |
With averaging | 100 µV system limit |
Clock recovery and pattern sync trigger (PicoScope 9211A only) |
|
Clock recovery sensitivity | |
12.3 Mb/s to 1 Gb/s | 50 mV p-p |
1 Gb/s to 2.7 Gb/s | 100 mV p-p Continuous rate |
Pattern sync trigger | 10 Mb/s to 8 Gb/s with pattern length from 7 to 65,535 max. |
Recovered clock RMS trigger jitter, maximum | 1 ps + 1.0% of unit interval |
Maximum safe trigger input voltage | ±2 V (DC + peak AC) |
Trigger input connector | SMA (F) |
Signal generator output (PicoScope 9211A and 9231A) |
|
Modes | Step, coarse timebase, pulse, NRZ, RZ |
Rise/fall times | 100 ps (20% to 80%) typical |
Measurement and analysis |
|
Marker | Vertical bars, horizontal bars (measure volts) or waveform markers (× and +) |
Automatic measurements | Up to 40 automatic pulse measurements |
Histogram | Vertical or horizontal |
Mathematics | Up to four math waveforms can be defined and displayed |
FFT | Up to two fast Fourier transforms can be run simultaneously with the built-in filters (rectangular, Nicolson, Hann, flat-top, Blackman–Harris and Kaiser–Bessel) |
Eye diagram | Automatically characterizes NRZ and RZ eye patterns. Measurements are based on statistical analysis of the waveform. |
Mask test | Acquired signals are tested for fit outside areas defined by up to eight polygons. Standard or user-defined masks can be selected. |
Display |
|
Display resolution | Variable |
Display style | Dots, vectors, variable or infinite persistence, variable or infinite grey scaling, variable or infinite colour grading |
Environmental |
|
Temperature range (operating) | +5 °C to +35 °C |
Temperature range (stated accuracy) | +15 °C to 25 °C |
Temperature range (storage) | -20 °C to +50 °C |
Humidity range (operating) | Up to 85% RH, non-condensing, at +25 °C |
Humidity range (storage) | Up to 95% RH, non-condensing |
Physical properties |
|
Dimensions | 170 x 255 x 40 mm (6.7 x 10.0 x 1.6 in) |
Weight | 1.1 kg (2.3 lb) max. |
Software |
|
PicoScope 9000 for Windows | PicoScope 9000 software is capable of many advanced features such as mathematical analysis, histogram analysis, eye-diagram analysis and mask testing. All features are included as standard. Updates can be downloaded for free. |
Software development kit | The SDK allows you to control the scope from your own program. The software can act as an ActiveX COM server, allowing any program to send commands to it using a standard Windows protocol. This is ideal for production and test environments where multiple scopes need to be controlled from a single PC, or where automated tests need to be run. The SDK contains full documentation and example code for various programming languages. |
Languages | English |
General |
|
Additional hardware (supplied) | 2 x SMA M-F connector savers (supplied fitted to scope) Additional SMA M-F connector saver (9221A and 9231A only) TDR Accessory Kit (PicoScope 9211A and 9231A only) LAN patch and crossover cables (9211A and 9231A only) USB 2.0 cable AC adaptor Tough carry case |
TDR Accessory Kit contents (supplied with PicoScope 9211A and 9231A only) | 30 cm precision cable 80 cm precision cable 0 Ω short 50 Ω terminator Coupler Resistive power divider SMA wrench |
Operating system | 32-bit edition of Windows XP (SP3), 32 or 64-bit edition of Windows Vista, Windows 7 or Windows 8 (not Windows RT) |
PC connection | USB 2.0 (USB 1.1 and USB 3.0 compatible) |
LAN connection | 10/100 Mb/s (PicoScope 9211A and 9231A only) |
Power supply | |
PicoScope 9201A | +6 V DC ±5%. @ 1.9 A max |
PicoScope 9211A | +6 V DC ±5%. @ 2.6 A max |
PicoScope 9221A | +6 V DC ±5%. @ 2.3 A max |
PicoScope 9231A | +6 V DC ±5%. @ 2.9 A max |
AC adaptor | Mains adaptor supplied for USA, UK, Europe and Australasia |
Compliance |
FCC (EMC), CE (EMC and LVD) |
Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |
Warranty | 2 years (1 year for input sampler) |
Discover out models range
9201A | 9211A | 9231A | |
---|---|---|---|
12 GHz sampling oscilloscope | |||
USB port | |||
LAN port | |||
Clock recovery trigger | |||
Pattern sync trigger | |||
Dual signal generator outputs | |||
Electrical TDR/TDT capability | |||
8 GHz optical-electrical converter | |||
Accessories included | |||
Price | €8 815 | €11 015 | €20 575 |
Buy now | 9201A | 9211A | 9231A |